TK series

Strain gages for measuring the axial tensile force of bolts. These strain gages are mounted in bolts (drilling and cleaning required) before their installation. Then, it is possible to measure the strecthing of the bolt during its tightening and testing or operation of the detail where it is installed.

Characteristics

DesignationTK120‐3AA1.8(**)‐G80TK120‐5AA1.8(**)‐G80
Nominal base length, mm35
Overall dimensions, mmØ1,9 х 8,0Ø1,9 х 11,0
Gage Resistance (nominal):120±1,0
Gage factor2,0 … 2,2
STC codes9, 11, 16, 23
Working temperature rang(°C)‐10…+80

Configuration

DesignationDesignDiameter, mmа, ммb, ммc, mm (length of lead wires)
TK120‐3AA1.8(**)‐G80one-component1,93880
TK120‐5AA1.8(**)‐G80two-component511